INSTALLATION REQUIREMENTS


It is condition of installation of all Billi supplied products, whether by sale, rent or other means, that the Customer ensures the following requirements exist at the premises in which the Billi supplied products will be installed:

(i) a 1⁄2 inch stop tap must exist and be located within 600mm of the inlet of the Billi supplied products and within the same cabinet in which the Billi supplied products is to be installed;

(ii) the water supply pressure to the Billi supplied products must be between 250kPa and 1,000kPa;

(iii) the water supply temperature to the Billi supplied products must be between 5°C and 30°C;

(iv) a spare 3 pin GPO is required and must be located within 1 metre of the Billi supplied products and within the same cabinet in which the Billi supplied products is to be installed. The 3 pin GPO must be:

(i) 10 amp rated for Quadra Compact, 420,440, 460, Plus 5, Plus 9, Alpine, Sahara 320, 360 and Kwikwash models;

(ii) 15 amp rated for Quadra 4100, Plus 15, Sahara 3120 models;

(iii) 20 amp rated for the Quadra 4180 model.

(v) a dedicated, residual current leakage device (RCD) protected circuit should be provided;

(vi) for Quadra, Alpine and B-3000 water cooled models, a drainage point, such as a dishwasher nipple or sink trap, must exist and be located within the same cabinet in which the Billi supplied products s to be installed;

(vii) for Eco and B-5000 air cooled models, adequate airspace and an unobstructed clearance of not less than 25mm on each side of the under bench unit in which the Billi supplied products is to be installed;

(viii) for Quadra air cooled models, cabinet ventilation, adequate airspace and an unobstructed clearance of at least 25mm minimum on each side of the under bench unit. Door ventilation is to be provided in the bottom and top of the cabinet door; and

(ix) The Billi supplied products must be located with 800mm of the tap base, be accessible for service and be able to be installed and removed without alteration or modification of the cabinet in which the Billi supplied products is to be located.

Billi shall be entitled to the Customer an installation fee, at prevailing Billi scheduled rates, for installation on granite bench tops, stone bench tops or bench tops that are greater than 48mm in thickness.

Whilst Billi will exercise due skill and care in undertaking such work to prevent any damage to a stone bench top, given the inherent risks associated with the possibility of chipping or cracking as a consequence of undertaking such work, Billi shall not be held liable for any damage that may be caused to the stone bench top as a consequence.